Gigabyte GS-R12T4H2-RH Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Kluczowe komponenty serwerowe Gigabyte GS-R12T4H2-RH. GIGABYTE GS-R12T4H2-RH User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 81
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Service Guide
GIGABYTE
GS-R12T4H2-RH
1U Rack Mount Server
Dual Intel
®
Xeon LGA1366 Processor Serverboard
Rev. 1.0
Przeglądanie stron 0
1 2 3 4 5 6 ... 80 81

Podsumowanie treści

Strona 1 - 1U Rack Mount Server

Service GuideGIGABYTEGS-R12T4H2-RH 1U Rack Mount ServerDual Intel® Xeon LGA1366 Processor ServerboardRev. 1.0

Strona 2

10GS-R12T4H2-RH Rack Mount Server (Support RAID 0, 1, 1E) (Option)Super I/OController  ITE IT8720F Super I/OFront I/O  2 X USB 2.0 connectorRea

Strona 3 - Table of Contents

11GS-R12T4H2-RH Rack Mount ServerPre-installation InstructionsPerform the steps below before you open the server or before you remove or replaceany co

Strona 4

12GS-R12T4H2-RH Rack Mount ServerRemove the chassis cover.Step 1 Loosen the screw on the front chassis cover.Step 2 Push down the indentation located

Strona 5 - Network Options

13Hardware Installation ProcessInstalling the ProcessorPlease make sure the CPU type and speed that are supported by the motherboard.Step 1 Raise the

Strona 6

14GS-R12T4H2-RH Rack Mount ServerInstalling the Heat SinkStep 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please wellre

Strona 7

15GS-R12T4H2-RH Rack Mount ServerInstalling the Memeory ModuleStep 1. Insert the DIMM memory module vertically into the DIMM slot, and push it down.S

Strona 8 - Class A equipment

16Hardware Installation ProcessCPU1CPU2123456789101213141617181115No. Code No. Code 1 DDR_P1C2D0 10 DDR_P0C0D2 2 DDR_P1C2D1 11 DDR_P0C0D1 3 DDR_P1C2D2

Strona 9 - System Specification

17Hardware Installation ProcessU-DIMM Population TableP0C0D0P1C0D0P0C0D1P1C0D1P0C0D2P1C0D2P0C1D0P1C1D0P0C1D1P1C1D1P0C1D2P1C1D2P0C2D0P1C2D0P0C2D1P1C2D1

Strona 10

18GS-R12T4H2-RH Rack Mount ServerR-DIMM Population TableP0C0D0P1C0D0P0C0D1P1C0D1P0C0D2P1C0D2P0C1D0P1C1D0P0C1D1P1C1D1P0C1D2P1C1D2P0C2D0P1C2D0P0C2D1P1C2

Strona 11 - System Hardware Installation

19Hardware Installation ProcessInstalling the PCI Expansion CardStep 1 Lift the riser bracket slightly, then pull it out from the server chassis.Step

Strona 12 - Remove the chassis cover

PrefaceBefore using this information and the product it supports, please read the following general information.1. This Service Guide provides you wit

Strona 13 - Installing the Processor

20GS-R12T4H2-RH Rack Mount Server345656

Strona 14 - Installing the Heat Sink

21GS-R12T4H2-RH Rack Mount ServerInstalling the Hard Disk DriveStep 1 Press the release button.Step 2 Pull the locking lever to remove the HDD tray.St

Strona 15 - Installing the Memeory Module

22Hardware Installation ProcessHDD Security LockThe HDD bays incorporate a security screw to prevent accidental HDD release.To engage the lock, turn t

Strona 16 - Hardware Installation Process

23GS-R12T4H2-RH Rack Mount ServerInstalling and Replacing the FAN DuctStep 1 Remove the airducts from the chassis by pulling the rear edge in the dire

Strona 17 - U-DIMM Population Table

24Hardware Installation ProcessReplacing the FAN AssembllyStep 1 Remove thefan assemble pulling the rear edge in the direction of the arrowStep 2 Lift

Strona 18 - R-DIMM Population Table

25GS-R12T4H2-RH Rack Mount ServerReplacing the MotherboardStep 1 Remove the chassis cover. See Removing the Chassis Cover on page 12.Step 2 Remove the

Strona 19

26Hardware Installation ProcessReplacing the Power SupplyStep 1 Remove the fanduct from the chassis by pulling the rear edge.Step 2 Disconnect the t

Strona 20

27GS-R12T4H2-RH Rack Mount Server

Strona 21

28GS-R12T4H2-RH Rack Mount ServerReplacing the Chassis CoverStep 1 Replace the cover, and slide the chassis in the direction of the arrow  until the

Strona 22 - HDD Security Lock

29GS-R12T4H2-RH Rack Mount ServerFront View of GS-R12T4H2-RHAppearance of GS-R12T4H2-RHNOTE! For Front LED description, please go to Front Panel LED I

Strona 23

3GS-R12T4H2-RH Rack Mount ServerTable of ContentsPreface...

Strona 24 - Replacing the FAN Assemblly

System Appearance30Rear View of GS-R12T4H2-RH31 2 3 456 789 1. Power Module Connect the power cable to the socket. 2. PS/2 port Connect the keyboard a

Strona 25 - Replacing the Motherboard

31LED DescriptionFront Panel LED Indicator234156No Indicator 1 Powerstatus 2 System ID 3 Systemstatus 4 HDDactivityColor State DescriptionGreen On Sys

Strona 26 - Replacing the Power Supply

32GS-R12T4H2-RH Rack Mount ServerColor State DescriptionGreen On Link between system andnetwork or no accessGreen Blink Network accessGreen On Link be

Strona 27

33GS-R12T4H2-RH Rack Mount ServerLAN port LED IndicatorNo Name 1 Speedindicator2 Link/activityindicatorColor State DescriptionN/A Off 10Mbps con

Strona 28 - Replacing the Chassis Cover

34LED DescriptionHard Disk Drive LED Description Description HDD Prsent HDD access HDD failure HDD removed HDD connected and rebuilding data

Strona 29 - Appearance of GS-R12T4H2-RH

35GS-R12T4H2-RH Rack Mount ServerGC-BS14U-RH Back plane board Components2143107511136891214151817161920 21 22 2324 25 26 27No Code Description 1 P2 Po

Strona 30 - Rear View of GS-R12T4H2-RH

36GS-R12T4H2-RH Rack Mount ServerSystem Block DiagramVRD 11.1VRD 11.1CPU2Nehalem-EPProcessorLGA1366Port 1CPU1Nehalem-EPProcessorLGA1366Port 1QPIQPIINT

Strona 31 - Front Panel LED Indicator

37GS-R12T4H2-RH Rack Mount ServerConnector Icon DescriptionSuggest IconDescriptionKeyboardVGAMouseLANCOMUSB

Strona 32

38Motherboard ComponontsGA-7TTSE-RH Motherboard ComponentMotherboard Placement and Jumper Setting234156910711121315142181618192022172324

Strona 33 - LAN port LED Indicator

39GS-R12T4H2-RH Rack Mount ServerItem Component1. Processor 1 socket2. Processor 2 socket3. SATA data cable cable connectors4. USB connector for inter

Strona 34

4Table of ContentAdvanced ... 47Processor Configuratio

Strona 35

40Jumper SettingJumper Setting2134567 1 ) BIOS_RVCR1 (BIOS Revocery jumper)1-2 close: Normal operation. (Default setting)2-3 close: Enable BIOS Recov

Strona 36 - System Block Diagram

41GS-R12T4H2-RH Rack Mount Server 5 ) PASS_DIS1 (Skip Supervisor password jumper)111-2 Close: Normal operation. (Default setting)2-3 Close: Clear Su

Strona 37 - Connector Icon Description

42Jumper SettingExpansion Card Components DescriptionThe two riser cards installed in the PCI riser card bracket assembly povides support for both ful

Strona 38

43GS-R12T4H2-RH Rack Mount Server<> Move to previous item<> Move to next item<> Move to the item in the left hand<> Move t

Strona 39

44BIOS SetupGETTING HELPMain MenuThe on-line description of the highlighted setup function is displayed at the bottom of the screen.Status Page Setup

Strona 40 - Jumper Setting

45GS-R12T4H2-RH Rack Mount ServerSystem Date Set the System Date. Note that the “Day” automatically changed after you set the date.System Time The tim

Strona 41

46BIOS SetupTotal MemoryThe BIOS determines how much total memory is present during the POST.

Strona 42

47BIOS SetupFigure 2: AdvancedAdvancedAbout This Section: AdvancedWith this section, allowing user to configure your system for advanced operation. Us

Strona 43 - BIOS Setup

48GS-R12T4H2-RH Rack Mount ServerProcessor Configuration

Strona 44

49BIOS SetupProcessor ConfigurationThis category includes the Processor information of CPU Speed, Processor ID ,ProcessorL2 / L3 Cache, and QPI Freque

Strona 45 - Processor Information

5GS-R12T4H2-RH Rack Mount ServerSafety, Care and Regulatory Information Important safety informationRead and follow all instructions marked on the pr

Strona 46 - Total Memory

50GS-R12T4H2-RH Rack Mount ServerMachine CheckingEnabled Enable Machine Checking. (Default setting)Disabled Disable Machine Checking.Fast String Opera

Strona 47 - Advanced

51GS-R12T4H2-RH Rack Mount ServerProcessor Power ManagementFigure 2-1-1: Processor Power ManagementEIST (GV3) & C StateEnabled Enable EIST (GV3) a

Strona 48 - Processor Configuration

52BIOS SetupSW_ALL In SW_ALL mode, the OS Power Manager is responsible for coordinatingthe P-state among loical processors with dependencies and must

Strona 49 - A20M Support

53GS-R12T4H2-RH Rack Mount Serverstate. (Default setting)Disabled Disable CPU C6 Report.CPU C7 ReportEnabled Desire state for the Nehalem core C7 stat

Strona 50 - Machine Checking

54BIOS SetupMemory Configuration

Strona 51 - Processor Power Management

55GS-R12T4H2-RH Rack Mount Server Memory InformationThese following items display all information of current Base Memory, Extended Memory,, and instal

Strona 52

56BIOS SetupAdvanced Chipset Configuration

Strona 53 - ACPI MWAIT extensions

57GS-R12T4H2-RH Rack Mount ServerFigure 2-3-1: Intel VT for Directed I/O (VT-d)

Strona 54 - Memory Configuration

58BIOS SetupIntel VT for Directed I/O (VT-d)Enabled Intel VT for Directed I/O (VT-d). (Default setting)Disabled Disable Intel VT for Directed I/O (VT-

Strona 55

59GS-R12T4H2-RH Rack Mount Server2GB Select 2GB as granularity of PCI hole.QPI Control SettingsEnabled Enable QPI Control settings. (Default setting)D

Strona 56

6Safety Information* To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord.* Do not plug a modem or telephone cable i

Strona 57

60BIOS SetupPCI ConfigurationFigure 2-4: PCI ConfigurationOnboard LAN iSCSI Boot ROMEnabled Enable Onboard LAN iSCSI Boot ROM.Disabled Disable this f

Strona 58

61GS-R12T4H2-RH Rack Mount ServerLAN2Option ROMEnabled Enable onboard LAN2 device and initialize device expansionROM. (Default setting)Disabled Disab

Strona 59

62GS-R12T4H2-RH Rack Mount ServerSATA ConfigurationFigure 2-5: SATA Configuration

Strona 60 - PCI Configuration

63BIOS SetupSerial ATAEnabled Enables on-board serial ATA function. (Default setting)Disabled Disables on-board serial ATA function. Native Mode Ope

Strona 61 - Legacy USB Support

64BIOS SetupAuto: Set parameters automatically. (Default setting)CD-ROM: Use for ATAPI CD-ROM drives or double click [Auto] to set all HDD parametersa

Strona 62 - SATA Configuration

65BIOS SetupI/O DeviceConfigurationSerial Port A This allows users to configure serial prot A by using this option.Enabled Enable the configuration.

Strona 63 - SATA Port 0/1/2/3/4/5

66GS-R12T4H2-RH Rack Mount ServerBase I/O Address/IRQ3F8/IRQ4 Set IO address to 3F8/IRQ4.2F8/IRQ3 Set IO address to 2F8/IRQ3. (Default setting)3E8/IRQ

Strona 64

67BIOS SetupBoot DeviceConfigurationBoot -time Diagnostic ScreenWhen this item is enabled, system will shows Diagnostic status when system boot.Enable

Strona 65 - I/O DeviceConfiguration

68GS-R12T4H2-RH Rack Mount ServerNumLockThis option allows user to select power-on state for NumLock.On Enable NumLock. (Default setting)Off Disable t

Strona 66 - Base I/O Address/IRQ

69BIOS SetupThermal and Acoustic ConfigurationFigure 2-8: Thermal and Acoustic ConfigurationOpen loop Thermal ThrottleEnabled Open loop Thermal Thrott

Strona 67 - Boot DeviceConfiguration

7GS-R12T4H2-RH Rack Mount Serverthe FCC.Your telephone company may make changes in its facilities, equipment, operations, or procedures thatcould affe

Strona 68 - Off Disable this function

70GS-R12T4H2-RH Rack Mount ServerClose loop Thermal ThrottleEnabled Close loop Thermal Throttle. (Default setting)Disabled Disable Close loop Thermal

Strona 69

71GS-R12T4H2-RH Rack Mount ServerPowerFigure 3: PowerAfter Power FailureThis option provides user to set the mode of operation if an AC / power loss o

Strona 70

72BIOS SetupSecurityFigure 4: SecuritySet Supervisor PasswordYou can install and change this options for the setup menus. Type the password up to 6cha

Strona 71 - After Power Failure

73GS-R12T4H2-RH Rack Mount ServerSet User PasswordYou can only enter but do not have the right to change the options of the setup menus. Whenyou selec

Strona 72 - Security

74BIOS SetupServerFigure 5: Server

Strona 73 - Password on boot

75GS-R12T4H2-RH Rack Mount ServerSystem Management

Strona 74

76BIOS SetupSystem ManagementThis category allows user to view the system management features. Including information ofMotherboard Hardware informatio

Strona 75 - System Management

77GS-R12T4H2-RH Rack Mount ServerFigure 5-2: Console RedirectionConsole RedirectionConsole RedirectionIf this option is set to enabled, it will use a

Strona 76 - BMC IP Address Source

78BIOS SetupThis option allows user to set the specified baud rate.Options 300, 1200, 2400, 9600, 19.2K, 38.4K, 57.6K, 115.2K.Terminal TypeThis option

Strona 77 - Console Redirection

79GS-R12T4H2-RH Rack Mount ServerBootFigure 6: BootBoot Priority OrderThis field determines which type of device the system attempt to boot from afte

Strona 78 - Continue C.R. after POST

8Safety InformationNOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the totalload to be connected to a telephon

Strona 79 - Boot Priority Order

80BIOS SetupExitFigure 7: ExitAbout This Section: ExitOnce you have changed all of the set values in the BIOS setup, you should save yourchanges and e

Strona 80 - Exit Discarding Changes

81GS-R12T4H2-RH Rack Mount ServerLoad Settup Defaultif you highlight this item and press Enter, a dialog box asks if you want to install optimals

Strona 81 - Save Changes

9Feature SummaryMotherboard  GA-7TTSE-RHProcessor Supported  Supports dual Intel® Xeon® processors Intel Xeon® Dual-Core/Quad-Core processor in L