Gigabyte GA-7PESH3 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Płyty główne Gigabyte GA-7PESH3. Gigabyte GA-7PESH3 motherboard Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 91
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
GA-7PESH3
Dual LGA2011 sockets motherboard for Intel
®
E5-2600 series processors
User's Manual
Rev. 1002
Przeglądanie stron 0
1 2 3 4 5 6 ... 90 91

Podsumowanie treści

Strona 1 - GA-7PESH3

GA-7PESH3Dual LGA2011 sockets motherboard for Intel® E5-2600 series processorsUser's ManualRev. 1002

Strona 2 - Copyright

Hardware Installation - 10 -1-2 ProductSpecicationsCPU  Support for Intel® Xeon® E5-2600 series processors in the LGA2011 package  L3 cache vari

Strona 3 - Table of Contents

- 11 - Hardware InstallationStorage Interface(SATA)  Intel® C602 controller  2 x SATA 6Gb/s connectors (SATA0/SATA1)  4 x SATA 3Gb/s connectors (S

Strona 4

Hardware Installation - 12 -Hardware Monitor  System voltage detection  CPU/System temperature detection  CPU/System fan speed detection  CPU/Syst

Strona 5 - Box Contents

- 13 - Hardware Installation1-3 Installing the CPU and CPU Cooler1-3-1 Installing the CPUA. Locate the alignment keys on the motherboard CPU socket

Strona 6 - GA-7PESH3 Motherboard Layout

Hardware Installation - 14 -Step 1: Push the lever closest to the "unlock" marking "" (below referred as lever A) down and away fr

Strona 7

- 15 - Hardware Installation1-3-2 Installing the CPU CoolerRefer to the steps below to correctly install the CPU cooler on the motherboard. (Actual i

Strona 8

Hardware Installation - 16 -1-4-1 FourChannelMemoryCongurationThis motherboard provides eight DDR3 memory sockets and supports Four Channel Techn

Strona 9 - 1-1 Installation Precautions

- 17 - Hardware Installation1-4-2 Installing a Memory Before installing a memory module, make sure to turn off the computer and unplug the power cord

Strona 10 - 1-2 ProductSpecications

Hardware Installation - 18 -1-5 Back Panel ConnectorsUSB 2.0/1.1 PortTheUSBport supports the USB2.0/1.1specication. Use this portforUSB

Strona 11

- 19 - Hardware InstallationLinkActivity LEDLinkActivity LEDSpeed LED Speed LED 10/100 LAN Port10/100/1000 LAN PortLink/Activity LED:Link/Activity LED

Strona 12

Copyright© 2013 GIGA-BYTE TECHNOLOGY CO., LTD. All rights reserved.The trademarks mentioned in this manual are legally registered to their respective

Strona 13 - 1-3-1 Installing the CPU

Hardware Installation - 20 -1-6 Internal Connectors 1) ATX1 2) P12V_AUX1 3) P12V_AUX2 4) PWR_DET1 (PMBus) 5) CPU0_FAN (for primary CPU) 6) C

Strona 14

- 21 - Hardware InstallationRead the following guidelines before connecting external devices:• First make sure your devices are compliant with the co

Strona 15

Hardware Installation - 22 -P12V_AUX2DEBUG PORTG.QBOFM85411/2/3) ATX1/P12V_AUX1/P12V_AUX2 (2x4 12V Power Connector and 2x12 Main Power Connector)

Strona 16 - 1-4 Installing the Memory

- 23 - Hardware InstallationATX11312412ATX1F_PANELF_PANELF_AUDIOF_AUDIOF_USBCOMBMODEMSmart Card ReaderSPDIFAUX_INCD_INSecure Gigital /Memory StickSeri

Strona 17 - 1-4-3 DIMM Population Table

Hardware Installation - 24 -5/6/7/8/9/10) CPU0_FAN/CPU1_FAN/SYS_FAN1/SYS_FAN2/SYS_FAN3/SYS_FAN4 (CPU Fan/System Fan Headers) The motherboard ha

Strona 18 - 1-5 Back Panel Connectors

- 25 - Hardware InstallationPinNo. Denition 1 GND 2 TXP 3 TXN 4 GND 5 RXN 6 RXP 7 GNDPinNo. Denition 1 GND 2 TXP 3 TXN 4 GND 5 RXN 6

Strona 19 - - 19 - Hardware Installation

Hardware Installation - 26 -17/18/19/20) SAS01/SAS23/SAS45/SAS67 (SAS 6Gb/s Connectors) The SAS connectors conform to SAS 6Gb/s standard.PinNo. De

Strona 20 - 1-6 Internal Connectors

- 27 - Hardware Installation22) FRONT_USB (Front USB Headers) TheheadersconformtoUSB2.0/1.1specication.EachUSBheadercanprovidetwoUSBp

Strona 21

Hardware Installation - 28 -25) FAUDIO_ACZ (Front Panel Audio Header) ThefrontpanelaudioheadersupportsIntelHighDenitionaudio(HD)andAC&a

Strona 22

- 29 - Hardware InstallationThe front panel design may differ by chassis. A front panel module mainly consists of power switch, reset switch, power LE

Strona 23 - - 23 - Hardware Installation

- 3 -Table of ContentsBox Contents ...

Strona 24 - 4) PWR_DET1 (PMBus connector)

Hardware Installation - 30 -27) BP_1 (HDD Back Plane Board Hearders)1 225 26PinNo. Denition 1 AST2300_SCGCLK 2 FM_THROTTLE_AND_N 3 AST2300_SGLD

Strona 25

- 31 - Hardware Installation31) SATA_SGPIO1 (SATA SGPIO Headers) SGPIO is stands for Serial General Purpose Input/Output which is a 4-signal (or 4-w

Strona 26 - Hardware Installation - 26

Hardware Installation - 32 -32) IPMB1 (IPMB Connector)PinNo. Denition 1 SCL 2 GND 3 SDAPinNo. Denition 1 GND 2 SPDIF_OUT131 233) SPDIF_OU

Strona 27 - - 27 - Hardware Installation

- 33 - Hardware Installation34) BMC_LED1 (BMC Firmware Readiness LED)35) RAIDKEY1 (LSI RAID Key Header)State DescriptionOn BMCrmwareisinitialBl

Strona 28

- 34 - Hardware Installation36) BAT1 (Battery) Thebatteryprovidespowertokeepthevalues(suchasBIOScongurations,date,andtimeinformation

Strona 29

- 35 - Hardware Installation 1) CLR_CMOS1 2) BIOS_WP1 3) CHASSIS_OP 4) SSB_ME1 5) S3_MASK 6) PASWWORD1 7) BIOS_RVCR1 8) BMC_FRB1 9) PMBUS_SEL

Strona 30 - Hardware Installation - 30

Hardware Installation - 36 -1) CLR_CMOS1 (Clearing CMOS Jumper)  Usethisjumper to cleartheCMOS values (e.g.dateinformation and BIOScon

Strona 31

- 37 - Hardware InstallationOpen: Normal operation.Closed: Active chassis intrustion alert.3) CASSIS_OP (Case open intrusion header)1-2 Close: Normal

Strona 32 - 32) IPMB1 (IPMB Connector)

Hardware Installation - 38 -5) S3_MASK (S3 Power On Select Jumper) 2-3 Close: Keep initial power on. (Default setting)1-2 Close: Stop an initial powe

Strona 33 - - 33 - Hardware Installation

- 39 - Hardware Installation2-3 Close: BIOS recovery mode.1-2 Close: Normal operation. (Default setting)7) BIOS_RVCR1 (BIOS Recovery Jumper)11118) B

Strona 34 - 36) BAT1 (Battery)

- 4 -2-4 Security Menu ... 782-5 Server Management Menu

Strona 35 - 1-7 Jumper Settings

Hardware Installation - 40 -10/11) SATA_DOM0/SATA_DOM1 (SATA DOM Jumpers) 112-3 Close: PMBus connects to BMC. (Default setting)1-2

Strona 36 - Hardware Installation - 36

- 41 - BIOS SetupBIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions inc

Strona 37 - - 37 - Hardware Installation

BIOS Setup - 42 - Main This setup page includes all the items in standard compatible BIOS. Advanced This setup page includes all the items of BI

Strona 38 - Hardware Installation - 38

- 43 - BIOS Setup2-1 The Main MenuOnce you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move

Strona 39 - - 39 - Hardware Installation

BIOS Setup - 44 - BIOS Information Project Version Display version number of the project. BIOS Build Date and Time Displays the date and time when

Strona 40

- 45 - BIOS Setup2-2 Advanced MenuTheAdvancedmenudisplaysubmenuoptionsforconguringthefunctionofvarioushardwarecomponents.Select a subm

Strona 41 - Chapter 2 BIOS Setup

BIOS Setup - 46 -2-2-1 PCI Subsystem Settings

Strona 42

- 47 - BIOS Setup PCI Express Slot #1/2/3/4/5 I/O ROM When enabled, This setting will initialize the device expansion ROM for the related PCI-E slo

Strona 43 - 2-1 The Main Menu

BIOS Setup - 48 -2-2-1-1 PCI Express Settings PCI Express Device Register Settings Relaxed Ordering Enable/DIsable PCI Express Device Relaxed Ord

Strona 44

- 49 - BIOS Setup Link Training Retry DenethenumberofRetryAttemptssoftwarewiltaketoretrainthelinkifprevioustrainingattemptwasunsu

Strona 45 - 2-2 Advanced Menu

- 5 -Box Contents GA-7PESH3 Motherboard Driver CD Two SATA cables I/O Shield CPU Power cables• The box contents above are for referenc

Strona 46 - 2-2-1 PCI Subsystem Settings

BIOS Setup - 50 -2-2-2 Runtime Error Logging Runtime Error Logging Enable/Disable Runtime error logging support. Options available: Enabled/Disa

Strona 47

- 51 - BIOS Setup2-2-3 CPUConguration

Strona 48 - 2-2-1-1 PCI Express Settings

BIOS Setup - 52 - CPU Information Socket 0/1 CPU Information CPU Type/ Signature / Microcode Patch / Max CPU Speed / Min CPU Speed / Processor Cor

Strona 49 - Unpopulated Links

- 53 - BIOS Setup Limit CPUID Maximum When enabled, the processor will limit the maximum CPUID input values to 03h when queried, even if the process

Strona 50 - 2-2-2 Runtime Error Logging

BIOS Setup - 54 -2-2-3-1CPUPowerManagementConguration CPUPowerManagementConguration Power Technology Congurethepowermanagementfeatur

Strona 51 - 2-2-3 CPUConguration

- 55 - BIOS Setup CPU C3/C6 Report (Note) Allows you to determine whether to let the CPU enter C3/C6 mode in system halt state. When enabled, the CP

Strona 52

BIOS Setup - 56 -2-2-4 USBConguration USBConguration Legacy USB Support Enables or disables support for legacy USB devices. Options avail

Strona 53

- 57 - BIOS Setup2-2-5 SATAConguration

Strona 54 - Turbo Mode

BIOS Setup - 58 -(Note) This item is will not appear when the SATA mode is set ot RAID mode.  SATAConguration SATA Port 0/1/2/3/4/5 (Note) Dis

Strona 55 - Energy Performance

- 59 - BIOS Setup2-2-6 InfoReportConguration InfoReportConguration Post Report Post Report Enable/Disable Post Report support. Options ava

Strona 56 - 2-2-4 USBConguration

- 6 -GA-7PESH3 Motherboard Layout5354343536375557564364636258 59 60 616665 71383940333231414247484950515227282930454446121315162324252619202112 3 4 67

Strona 57 - 2-2-5 SATAConguration

BIOS Setup - 60 -2-2-7 SuperIOConguration

Strona 58

BIOS Setup - 61 - SuperIOConguration Super IO Chip Display the model name of Super IO chipset. SerialPort0/1Conguration Serial Port  W

Strona 59 - Info Error Message

BIOS Setup - 62 -2-2-8 Serial Port Console Redirection

Strona 60 - 2-2-7 SuperIOConguration

- 63 - BIOS Setup COM1/Serial Port for Out-of Band Management / Windows Emergency Management Service (EMS) Console Redirection (Note)  Sel

Strona 61

BIOS Setup - 64 - Parity A parity bit can be sent with the data bits to detect some transmission errors. Even: parity bi is 0 if the num of 1&a

Strona 62 - BIOS Setup - 62

- 65 - BIOS Setup2-2-9 Network Stack Network stack Enable/Disable UEFI network stack. Options available: Enabled/DIsabled. Default setting is

Strona 63

BIOS Setup - 66 -2-2-10 Intel (R) 82574L Gigabit Network Connection

Strona 64

- 67 - BIOS Setup PORT CONFIGURATION MENU NICConguration Link Speed Change link speed duplex for current port. Options available: AutoNeg/1

Strona 65 - 2-2-9 Network Stack

BIOS Setup - 68 -2-3 Chipset MenuTheChipsetmenudisplaysubmenuoptionsforconguringthefunctionofNorthBridgeandSouthBridge.Select a subm

Strona 66 - BIOS Setup - 66

- 69 - BIOS Setup2-3-1 North Bridge

Strona 67

- 7 -Item Code Description1 AUDIO1 Audio connectors2 USB_MLAN BMC Management LAN port (top) / USB ports (bottom)3 USB_GLAN1 LAN1 port (top) / USB po

Strona 68 - 2-3 Chipset Menu

BIOS Setup - 70 - IOHConguration Press[Enter]forcongurationofadvanceditems. QPIConguration Press[Enter]forcongurationofadvanced

Strona 69 - 2-3-1 North Bridge

- 71 - BIOS Setup Patrol Scrub Enable/Disable Patrol Scrub function. Options available: Enabled/Disabled. Default setting is Enabled. Demand Scru

Strona 70

BIOS Setup - 72 -2-3-1-1IOHConguration

Strona 71

- 73 - BIOS Setup IOHConguration Intel(R)VTforDirectedI/OConguration Press[Enter]forcongurationofadvanceditems. Intel(R) I/OAT (In

Strona 72 - 2-3-1-1IOHConguration

BIOS Setup - 74 -2-3-1-2QPIConguration Current QPI Link Speed/ Current QPI Link Freq Displays the current QPI Link Speed and Frequency informatio

Strona 73

- 75 - BIOS Setup2-3-1-3 DIMM Information CPU Socket 0/1 DIMM Information CPU Socket 0: DDR3_P0_A0/DDR3_P0_B0/DDR3_P0_C0/DDR3_P0_D0 Status The siz

Strona 74 - 2-3-1-2QPIConguration

BIOS Setup - 76 -2-3-2 SouthBridgeConguration PCH Information Name/Stepping Information Displays the name and stepping information of the south

Strona 75 - 2-3-1-3 DIMM Information

- 77 - BIOS Setup2-3-3 Intel ME Subsystem MESubsystemConguration Enable/DisableMEsubsystemconguration. Options available: Enabled/Disabled

Strona 76

BIOS Setup - 78 -There are two types of passwords that you can set:• Administrator Password Entering this password will allow the user to access a

Strona 77 - 2-3-3 Intel ME Subsystem

BIOS Setup - 79 -2-5 Server Management Menu BMCLANConguration BMCLANConguration.PressEntertoaccesstherelatedsubmenu. Gbt BMC Funct

Strona 78 - 2-4 Security Menu

- 8 -45 BIOS_WP1 BIOS write protect jumper46 CLR_CMOS1 Clear CMOS jumper47 F_USB3_1 USB 3.0 connector48 FRONT_USB USB 2.0 connector49 BP_1 HDD back pl

Strona 79 - 2-5 Server Management Menu

- 80 - BIOS Setup Lan Channel 1 CongurationSource  SelecttocongureLANchannelparametersstaticallyordynamically(DHCP).Donothingop

Strona 80 - 2-5-1 BMCLANConguration

BIOS Setup - 81 -2-5-2 Gbt BMC Function Select NCSI and Dedicated LAN Switch NCSI and dedicated LAN and send KCS command. Options available: Mo

Strona 81 - 2-5-2 Gbt BMC Function

- 82 - BIOS Setup2-5-3 View FRU InformationThe System Management submenu is a simple display page for basic system ID information, as well as System

Strona 82 - 2-5-3 View FRU Information

BIOS Setup - 83 -2-5-4 System Event Log Enabling/Disabling Options SEL Components Change this to enable or disable all features of System Event L

Strona 83 - 2-5-4 System Event Log

- 84 - BIOS Setup2-6 Boot MenuThe Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error messageif

Strona 84 - 2-6 Boot Menu

BIOS Setup - 85 - Hard Drive BBS Priorities  PressEntertocongurethebootpriority. Network Device BBS Priorities  PressEntertocongureth

Strona 85 - CSM Parameters

- 86 - BIOS Setup2-6-1 CSM16 Parameters CSM16 Parameters CSM16 Module Version Display CSM Module version information. Gate20 Active Upon Reques

Strona 86 - 2-6-1 CSM16 Parameters

BIOS Setup - 87 - CSM parameters  PressEntertoconguretheadvanceditems. Launch CSM (Compatibility Support Module) Enable/Disable Compatibil

Strona 87 - 2-6-2 CSM Parameters

- 88 - BIOS Setup Other PCI device ROM priority ForPCIdevicesotherthanNetwork,MassstorageorVideodevice,deneswhichOpROMtolaunch. Opt

Strona 88 - Other PCI device ROM priority

BIOS Setup - 89 -2-7 Exit MenuThe Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press En

Strona 89 - 2-7 Exit Menu

- 9 - Hardware Installation1-1 Installation PrecautionsThe motherboard contains numerous delicate electronic circuits and components which can become

Strona 90 - Chapter 3 Appendix

- 90 - AppendixChapter 3 Appendix3-1 Regulatory StatementsRegulatory NoticesThis document must not be copied without our written permission, and the

Strona 91

Appendix - 91 -Finally, we suggest that you practice other environmentally friendly actions by understanding and using the energy-saving features of t

Komentarze do niniejszej Instrukcji

Brak uwag